DLR-CAT6-12C24

Novasub data sensor cable CAT6 & 12×24 AWG BS 500 kg

The DLR-CAT6-12C24 is a standard CAT6 cable which is added with 12×0,2 mm2 (12X24 AWG) cores. The CAT6 cable is a foiled 4x2x0,2 mm2 (4X2X24/7 AWG) Cat.6 F/UTP cable with an extra middle separator between the 4x twisted cores. The DLR-CAT6 is specially build for underwater use and is mechanical reinforced with a Vectran fiber braid and a PUR coated sheath. Around the middle CAT6 cable 12 pairs of 24 AWG (0.2 mm²) are twisted which can be used to power or control equipment. Length available up to 500 m.

Features
  • 1 Gbit Connection
  • Vectran fiber braid reinforced
  • PUR sheath
  • Flexible
Applications
  • HD IP cameras
  • LAN connections
  • ROV systems
  • Control systems

 

4x2x0,2 mm2 (4X2X24/7 AWG) Cat.6 F/UTP
  • Tinned copper conductor 7×0,20 mm
  • Foam skin polyethylene insulation
  • Cores twisted in pairs, pairs laid up with cross-web filler. Color code blue-white/blue, orange-white / orange, green-white/green, brown-white/ brown
  • Screen of polyester tape, tinned copper drain wire 7×0,20 mm, aluminum/polyester tape
  • PE sheath, Nominal diameter 7,60 mm, Color black
12×0,2 mm2 (12X24 AWG) power conductors
  • Tinned copper conductor 7×0,20 mm
  • PE insulation, Nominal thickness 0,15 mm
  • Nominal diameter 0,90 mm
  • Colors white, brown, green, yellow, grey, pink repeated 2 times in sequence
  • Conductors 24 AWG laid up around cat. 6 cable with polypropylene fillers
  • Protective polyester tape
  • Vectran fiber braid strength member
Outer Jacket (Hydrolysis resistant PUR outer sheath)
  • Nominal thickness 1,40 mm (color yellow)
  • Nominal diameter 12,6 mm
Marking: “www.novasub.com – DLR-CAT6-12C24 – (meter) m”
  • Cat. 6 characteristic impedance (1÷100MHz) : 100+/-15 Ω
  • Cat. 6 mutual capacitance : 48 pF/m
  • Electrical resistance conductors 24 AWG : <88,67ohm/km@20°C
  • Working voltage 0,22 mm² : 300 V
  • Weight in air nom. : 153 kg/km
  • Weight in fresh water nom. : 28 kg/km
  • Weight in sea water nom. : 25 kg/km
  • Breaking strength : 500 Kg
  • Working load max. : 125 Kg
  • Recommended static bending radius min. : 63 mm
  • Recommended dynamic bending radius min. : 126 mm
  • Working temperature : -40/+80°C