VLR-1CO-6C-1Q

Novasub MiniTV cable VLR-1CO-6C-1Q

Novasub developed and manufactured a multipurpose reinforced underwater MiniTV cable. Novasub Vectran fiber braid reinforced video cable for use of CCTV system in combination with diver communication and diver light. Length available up to 1000 m.

Features
  • Low cost
  • Vectran fiber braid reinforced
  • Extreme tough PUR sheath
  • Flexible
  • Very small bend radius
Applications
  • Diver umbilical (video, light and comm.)
  • CCTV systems with lights and data line
  • UW sensors power / control
  • Sonar power / control
  • Tow cable for any sensor
1 x COAX 75 OHM
  • Tinned copper conductor 7×0,16 mm
  • Foamed polyolefine insulation, nominal thickness 0,73 mm
  • Nominal diameter 1,95 mm
  • Tinned copper braid overall shield, coverage 95%
  • HDPE sheath, nominal thickness 0,30 mm, nominal diameter 2,95 mm, color black
2 x 0,75 mm2 power conductors
  • Tinned copper conductor IEC 60228 class 5
  • HDPE insulation, nominal thickness 0,40 mm
  • Nominal diameter 1,90 mm, colors red and black
1x4x0,2 mm2 (1 x 4 x 24 AWG) twisted shielded pairs
  • Tinned copper conductor 7×0,20 mm
  • HDPE insulation
  • Nominal thickness 0,25 mm
  • Nominal diameter 1,10 mm
  • Core twisted in quads, colors white, red, blue, yellow
  • Screen of aluminium/polyester tape
  • Tinned copper drain wire 7×0,20 mm
  • Polyester tape
4×0,2 mm2 (4 x 24 AWG) power conductors
  • Tinned copper conductor 7×0,20 mm
  • HDPE insulation, color white numbered 1-4
  • Nominal thickness 0,25 mm
  • Nominal diameter 1,10 mm
  • Elements laid up together
  • Protective polyester tape
  • Vectran fiber braid strength member
Outer Jacket (Hydrolysis resistant PUR outer sheath)
  • Nominal thickness 1,20 mm (color orange)
  • Nominal diameter 9,15 mm
Marking: “www.novasub.com VLR-1CO-6C-1Q (meter) m”
  • Electrical resistance conductor. 24 AWG < 88,67 ohm/km @ 20°C
  • Electrical resistance conductor. 0,75 mm2 < 26,70 ohm/km @ 20°C
  • Working voltage 24 AWG : 300 V
  • Working voltage 0,75 mm2 : 600 V
  • Coax nominal impedance : 75+/- 5 ohm
  • Weight in air nom. : 99 kg/km
  • Weight in fresh water nom. : 33 kg/km
  • Weight in sea water nom. (s.g. 1,026) : 31 kg/km
  • Breaking strength : 500 kg
  • Working load max. : 125 kg
  • Recom. static bending radius min. : 46 mm
  • Recom. dynamic bending radius min. : 92 mm
  • Working temperature : -40/ + 80 ºC